On this part, you can do settings about FXO busy detect.
Parameter | DBID_FXO_AUTO_BUSY_DETECT |
---|---|
Description | It disables or enables the FXO Busy Auto Detect feature. |
Permitted Values | 0-Disable 1-Enable |
Default | 1 |
Web UI | FXO > FXO > FXO Busy Detect > FXO Busy Auto Detect(200~500ms) |
Parameter | DBID_FXO_BUSY_DETECT_TIMES |
---|---|
Description | Detects the number of busy tones. The default number is three, the call ends when the number exceeds three. |
Permitted Values | Integer |
Default | 3 |
Web UI | FXO > FXO > FXO Busy Detect > Busy Tone Count(3~6) |
Parameter | DBID_FXO_BUSY_DETECT_HOLD |
---|---|
Description | It configures the busy tone detect Hold time. |
Permitted Values | Integer |
Default | 750 |
Web UI | FXO > FXO > FXO Busy Detect > Tone-on Duration(30~1000ms) |
Parameter | DBID_FXO_BUSY_DETECT_INTERVAL |
---|---|
Description | It configures the busy tone signal tone detection interval. |
Permitted Values | Integer |
Default | 750 |
Web UI | FXO > FXO > FXO1 Trunk Outing > Tone-off Duration(30~2000ms) |